F&K Estimatings Construction Estimating & Takeoffs

Dual plumbing adoption · Valley risers · No street pipe by default

Phoenix pipe totals are unsafe until the set names its plumbing book

Extending Phoenix pipe before you know the book is how fixture-unit math goes wrong. Since 1 August 2025 the city building ordinance has carried both the 2024 international plumbing code and the 2024 uniform plumbing code. Planning & Development will review whichever volume the permit set declares, with the local amendments in that ordinance. If the specification cites one and the riser notes cite the other, stop and list the clash. Do not translate between them in the dark.

Domestic hot, cold, recirculation, waste, and vent are separate materials. A desert recirculation loop is often drawn because of the wait for hot water in a long apartment wing. Count that loop only where the riser shows it. Water heaters, whether tank or tankless, are schedule counts. Interceptors for a restaurant are counts when the kitchen sheets exist. Irrigation backflow on the landscape plan is not this trade unless the plumber’s contract says so. Reclaimed-water piping, purple pipe where a campus or a plant note calls for it, is its own material and is easy to bury in the domestic total.

Off-site taps and sewer stubs are a civil or utility scope in this city more often than they are interior plumbing. Leave them off unless the invitation includes those sheets. Buried depth follows the profile. Frost is not the story in the basin.

The piping occupation Plumbers, Pipefitters, and Steamfitters is published for Phoenix-Mesa-Chandler at $33.95 hourly mean, May 2025 file OEUM003806000000047215203. The title includes sprinkler fitters, so it is the wrong single rate for a residential service crew and the wrong single rate for a fire-sprinkler crew. It is a reference, not a fixture price.

Send risers, plans, and a sentence naming the plumbing volume. No stack is televised.

Floor sinks, mop receptors, and trench drains are separate counts. Mixing valves are counts when the spec requires them at public lavatories. Trap primers are counts where the riser shows them. Cleanout covers that the finish spec upgrades are an extra count beside the fitting. A basis-of-design list is copied, not replaced. Gas piping stays out unless this contract holds fuel gas. Medical vacuum is not domestic water. Recirculation pumps and expansion tanks are schedule equipment. Storm leaders inside the building are not the retention pipe in the parking lot.

Hose bibbs on a plaza are counts and their discharge across a walking surface is noted so the membrane trade is not also charged for the same outlet. Water-heater pans and drains are counts when the detail shows them. Thermal expansion tanks are equipment. A manifold serving an apartment stack is a count plus the branch lengths the riser dimensions. Graywater piping, if a separate legend exists, is not folded into waste. Irrigation sleeves shown only on the landscape plan stay with landscape unless the plumber’s sheet repeats them.

Piping quantities before Phoenix’s dual plumbing adoption

Phoenix piping items that depend on the named book

Will you convert an IPC riser into UPC fixture units?

No. If the set mixes the two books the city adopted, that mix is listed as a conflict. The pipe is extended only under the volume the drawings consistently use.

Is reclaimed water just another domestic line?

No. Where the plans show a separate nonpotable system, it is a separate material. It is not assumed on a house that never drew it.

Does the piping wage include sprinklers?

The published occupation title includes sprinkler fitters. Do not treat the hourly mean as three different crew rates.

Phoenix piping references

Send Phoenix risers and name the plumbing book

Request a quote for paid estimating or quantity takeoff services. Share your trade scope, project location and bid deadline. We confirm the fee and deliverables before work starts. Fields marked * are required.

Contact and project details
Choose your phone country and enter your local number. Or enter a full number starting with + and its country code, regardless of the country selected.

Project Drawings (optional)

PDF, CAD/BIM, Office, ZIP or image documents. Up to 5 files, 25 MB each; account limits also apply.

No drawings attached. This field is optional.

    Already have a sharing link? Paste it here instead of uploading. Grant access to info@fandkestimatings.us; do not include passwords.

    Upload only documents you are authorized to share. Privacy policy. This request does not opt you into marketing messages.

    Prefer to discuss the scope first, or having trouble with the form? Email your project details or discuss your project on WhatsApp. Include your project location, trade scope and bid deadline.