Cooling loads · City energy book · Valley walls
Phoenix wall insulation is a cooling problem drawn on the section, not a heating R-value brought south
A Phoenix wall is usually trying to keep heat out, not hold heat in. Planning & Development has reviewed commercial energy under Ordinance G-7397 since the first of August 2025, on the 2024 energy model code with city edits. Measure the board, the batt, and the roof insulation the sections draw for that cooling job. A wall copied from a heating climate will show a different continuous layer. Do not “correct” the Phoenix section up to a northern table.
Stucco on wood or steel studs, masonry veneer, and tilt-up with an interior furred finish do not share a square foot of insulation. The tilt panel itself is concrete. Any insulation on the inside face is a separate area, often with hat channel the detail either shows or omits. Spray foam in a parapet or a rim is a small volume. Do not smear it across the whole elevation. Roof insulation above a deck is often the roofing contractor’s board. Leave it there unless this invitation says the insulation contractor holds the roof.
Radiant barriers and cool-roof notes live in the roof assembly when the designer put them there. They are not an extra inch of batt in the attic of a house that has no attic. Slab-edge insulation, uncommon in the basin and still sometimes drawn on a commercial energy form, is a linear foot at the perimeter the form identifies.
Building insulation workers in the Phoenix-Mesa-Chandler wage area are published at $22.59 hourly mean, May 2025 file OEUM003806000000047213103, occupation title Insulation Workers, Floor, Ceiling, and Wall. Mechanical pipe cover is a different job. The figure is not a price per square. Arizona’s January 2023 federal chart shows no state prevailing-wage statute. Federal money can still name a determination.
Upload the wall and roof sections plus the energy forms. Measurement stays on those sheets. No one is on a Valley scaffold.
Parapet backs and equipment-screen walls are vertical areas the roof plan often forgets. If the section shows insulation there, count it. If the section stops at the roof deck, do not wrap the screen. Hat channel and furring that hold a continuous board are lengths from the spacing on the detail. A manufacturer-only note with no spacing is a gap. Fire-safing at the top of a rated wall is a linear foot and is often a different installer. Leave it out of the batt total unless this invitation owns it. Window returns that the envelope section assigns to the insulation contractor are lengths around the opening, not a percent of wall.
Roof crickets that include insulation thickness are board feet from the taper diagram, and they stay with whichever trade the invitation names. Window-perimeter sealant assigned to the envelope contractor is a length around each opening. If the glazing package owns that bead, it is left out here. Below-grade dampproofing on a stem wall is a foundation area, included only with the foundation details, and it is not batt. A warehouse with a furred interior finish needs the furring height from the section. A missing height makes that area a gap rather than a full-wall assumption.
Insulation quantities without the Valley energy book
Phoenix insulation choices the cooling climate does not decide for you
Should every Phoenix attic get the same blown depth?
No. Use the depth on the section or the energy form. Houses, tilt warehouses, and flat commercial roofs are different assemblies.
Is roof board part of this package?
Only if the invitation gives the roof insulation to this contractor. Otherwise it stays with the roof trade.
Does $22.59 set the installed price?
No. That is the May 2025 hourly mean for building insulation workers in the metro wage area. Production is yours.