F&K Estimatings Construction Estimating & Takeoffs

Remote estimating for US contractor bids

Precision Thermal & Moisture Protection Estimating

Forensic material quantity takeoffs for commercial roofing, below-grade waterproofing, air/vapor barriers, and thermal insulation. Project-specific delivery in editable Excel sheets and color-coded PDF plan markups.

Single-trade material takeoff
$150–$1,000 typical
Typical delivery
Typically 24–48 hours after approval
Deliverables
Excel + marked-up PDFs

Final fee, deliverables and delivery date are confirmed after document review. Larger and multi-trade packages take longer. See scope-specific fees and timing.

Your next contractor bid

Request a thermal & moisture protection estimating quote

Send the current roof and wall sections, specifications and transition details for the envelope package. Identify which trades supply and install the roof-to-wall tie-ins. We confirm the deliverables, fee and delivery date in writing after document review.

Useful documents for this scope

  • Wall and roof sections with assembly tags
  • Air-barrier and waterproofing transition details
  • Envelope specifications and trade responsibility matrix

Assign the roof-to-wall interface once

Where both roof and wall drawings show the same transition, assign it to the agreed trade package and record the detail reference. Separate field membrane area from linear transitions and flag unresolved boundaries for clarification. Inspect the sample deliverable formats and tell us which outputs you need.

Remote support across the United States. View service areas.

Share your project details. Fields marked * are required.

Contact and project details
Include + and your international calling code.

Project Drawings (optional)

PDF, CAD/BIM, Office, ZIP or image documents. Up to 5 files, 25 MB each; account limits also apply.

No drawings attached. This field is optional.

    Upload only documents you are authorized to share. Privacy policy. This request does not opt you into marketing messages.

    Prefer to discuss the scope first, or having trouble with the form? Email your project details or discuss your project on WhatsApp. Include your project location, trade scope and bid deadline.

    Building Envelope: quantities, checks and quote requirements

    An envelope package coordinates roof, wall insulation, air barriers, waterproofing and joints across their assembly interfaces. Individual product takeoffs remain separate.

    Measurement and reporting basis

    • Roof and wall assembly area (SF)
    • Joint, flashing and transition lengths (LF)
    • Penetrations and termination accessories (EA)

    Documents to include

    • Wall and roof sections with assembly tags
    • Air-barrier and waterproofing transition details
    • Envelope specifications and trade responsibility matrix

    Also identify the current revision, addenda, project ZIP code, requested trades and bid deadline.

    A scope check before pricing

    Assign roof-to-wall and below-grade transitions to one package, then reconcile totals with roofing, insulation and waterproofing takeoffs. Do not count the same membrane under two trade contracts.

    Scope limits: Envelope design, energy modeling and weather-tightness certification are excluded.

    Worked estimating example

    Assign roof-to-wall transitions once

    A 200 LF roof-to-wall interface may appear in roofing and air-barrier documents. Including it in both subcontract totals can duplicate the transition scope.

    What the estimate should record
    Reconcile the detail reference and responsible package, then keep membrane SF, transition LF and penetration EA separate across the envelope summary.
    Resolve before pricing
    Who owns the transition, and which adjacent trade has expressly excluded it?

    US project coverage for building envelope

    For US projects, include the ZIP code and the location-sensitive inputs below.

    • Use the issued regional envelope specifications and assembly transitions rather than assuming a standard roof or wall system.
    • Identify supplier delivery costs and the responsible trade for roof-to-wall, below-grade and opening interfaces before combining the envelope package.

    The proposal records the pricing date, cost sources and unconfirmed allowances. Explore US service area information or send your project details for a scope quote.

    Use the document checklist above to request quantities only, a priced estimate or a review of an existing bid.

    Request a building envelope scope quote

    CSI Division 07 Estimating Overview

    Building envelope integrity is the primary defense against water intrusion and energy loss. Our estimators quantify every layer of the thermal and moisture protection envelope—from below-grade foundation membranes and drainage boards to exterior wall continuous air barriers, cavity wall mineral wool insulation, parapet flashings, and multi-ply commercial roof systems.

    Delivery Schedule
    Confirmed after document review
    Specification
    CSI Division 07
    Format
    Excel & PDF
    Software
    Bluebeam / PlanSwift

    Complete CSI Division 07 Scope Coverage

    Our estimators perform itemized takeoffs across all critical envelope divisions:

    07 10 00

    Damp-Proofing & Waterproofing

    Sheet membranes, bentonite clay panels, crystalline waterproofing, and elastomeric fluid coatings.

    07 21 00

    Thermal Insulation

    Continuous polyiso, extruded polystyrene (XPS), mineral wool, fiberglass batts, and spray polyurethane foam.

    07 27 00

    Air Barriers & Vapor Retarders

    Self-adhered sheet membranes, fluid-applied vapor permeable/impermeable air barriers, and transition flashing.

    07 50 00

    Membrane Roofing

    TPO, EPDM, PVC, built-up asphalt, and modified bitumen roofing systems with tapered insulation schemes.

    07 62 00

    Sheet Metal Flashing & Trim

    Parapet coping, gravel stops, counter-flashing, drip edges, reglets, and scupper boxes.

    07 84 00

    Firestopping & Smoke Seals

    Top-of-wall deflection joint firestopping, curtain wall perimeter fire containment, and rated pipe penetrations.

    Division 07 Takeoff Sample Spreadsheet

    Sample formula-driven Excel deliverable itemizing material counts, unit measures, and waste factors:

    Worked estimating example. Quantities show the stated scope and format; this is not a client project or a project-specific price quote.

    Material / Scope Item Base Qty Unit Waste / Lap Factor Estimator Note
    60-Mil TPO Single-Ply Mechanically Attached Roof Membrane 42,000 SF 10% Includes field rolls, perimeter half-sheets & seam welding allowance
    2.6in Rigid Polyisocyanurate (Polyiso) Roof Insulation (R-15) 84,000 SF 8% Two layers of 2.6in staggered with heavy-duty fasteners & 3in stress plates
    Self-Adhered Vapor Permeable Air & Water-Resistive Barrier (WRB) 28,500 SF 12% Includes primer, 6in overlap seams, and window penetration flashing tape
    Below-Grade 60-Mil Self-Adhering Sheet Waterproofing Membrane 14,800 SF 10% Applied to foundation cast-in-place concrete walls with primer & mastic
    Dimpled High-Density Polyethylene Foundation Drainage Core Board 14,800 SF 8% Includes filter fabric face, termination bar & perforated footing drain tie-in
    24-GA Kynar 500 Pre-Finished Parapet Wall Coping Cap (16in Width) 1,240 LF 6% Includes continuous 20-GA cleat, concealed splice plates & neoprene fasteners

    Frequently Asked Questions

    What is included in CSI Division 07 thermal and moisture protection estimating?

    Our Division 07 takeoffs encompass below-grade waterproofing (sheet membrane, bentonite, fluid-applied), foundation drainage composite boards, continuous exterior insulation (polyiso, XPS, mineral wool), fluid-applied air and water-resistive barriers (WRB), commercial roofing systems (TPO, EPDM, PVC, modified bitumen, standing seam metal), spray foam insulation, firestopping assemblies, and joint sealants/expansion joints.

    How do you calculate membrane waste and flashing details?

    We quantify roof squares, vertical parapet wall flashing heights, termination bars, gravel stops, coping caps, pitch pockets, and perimeter lap seams with lap, cut and waste allowances stated separately for the specified system and roof geometry.

    Do you estimate continuous building envelope insulation and vapor retarders?

    Yes. We detail continuous insulation (ci) square footages, fastener densities, thermal bridging breaks, self-adhering vapor permeable and non-permeable membranes, and transition tapes at window/curtain wall interfaces.

    What is the turnaround time for a Division 07 takeoff?

    Delivery depends on the drawing set, requested trade scope, pricing requirements and bid deadline. The delivery date, scope and revision coverage are confirmed in the written quote after document review.

    Bid-Risk Management

    Need Accurate Thermal & Moisture Protection Estimates?

    Upload your construction drawings and we will send a written quote confirming the scope, fee and delivery date after document review. The delivery date is confirmed after reviewing the drawing set and requested scope.

    Request Takeoff Quote

    Project scope and delivery are confirmed in the written quote.