Scope and deliverables
UL-Compliant Fireproofing Takeoffs
Fireproofing and firestopping estimating demands measured compliance with Underwriters Laboratories (UL) design standards. Calculating steel coating without accounting for member weight-to-perimeter (W/D) ratios or overspray loss on corrugated deck leads to severe bidding miscalculations.
At F&K Estimatings, our passive fire protection estimators cross-reference structural steel sizes against UL directories. We calculate board foot quantities for SFRM, mil thicknesses for intumescent paint, and line-item penetrations for MEP firestopping.
We provide transparent, audit-ready Excel schedules and color-coded markups on the delivery date confirmed in the written quote to help you win profitable contracts.
Scope, price, and delivery are confirmed after reviewing the project documents and requested deliverables.
Deliverables for your agreed scope
SFRM board-foot schedule
Spray-applied fire-resistive material quantified by member and rating, with overspray allowances stated separately from measured board footage.
Intumescent coating takeoff
Thin-film coating areas and dry-film thickness requirements taken from the steel schedule and the specified UL designs.
Penetration firestop counts
Every pipe, conduit and duct penetration through rated assemblies counted and paired with its UL system detail.
Joint and safing schedule
Top-of-wall joints, perimeter fire containment and expansion joints measured in linear feet from the rated-wall drawings.
Who this service supports
- Fireproofing Subcontractors
- Firestop Specialty Contractors
- General Contractors
- Industrial Painting Contractors
- Mechanical / Electrical Contractors
Fireproofing: quantities, checks and quote requirements
Fireproofing takeoffs measure sprayed and intumescent fireproofing by member and rating, and add firestopping at penetrations and joints.
Measurement and reporting basis
- Sprayed fire-resistive material by member (SF / BF)
- Intumescent coatings (SF)
- Firestopping at penetrations (EA)
- Joint systems (LF)
- Access equipment and protection
Documents to include
- Structural framing plans
- Code and life-safety plan with ratings
- Fireproofing specification and UL designs
Also identify the current revision, addenda, project ZIP code, requested trades and bid deadline.
A scope check before pricing
Separate sprayed fire-resistive material area and thickness from intumescent coating area and penetration EA. Follow specified assembly references; identify access and masking as separate scope.
Scope limits: Fire-rating design, product thickness approval and third-party inspection are excluded.
Worked estimating example
Preserve the specified assembly and thickness
Two steel areas with the same exposed SF can require different products or application thicknesses. A single area total does not establish material volume or an approved fire rating.
- What the estimate should record
- Group measured area by member or assembly reference, specified system and thickness basis. Keep masking, access and inspection requirements visible as separate scope.
- Resolve before pricing
- Which tested assembly references and product requirements are supplied by the design team?
Firestopping takeoff services and fireproofing quantities by specified assembly
A fireproofing takeoff should separate structural coatings from penetration and joint firestopping. Record the supplied assembly reference, thickness or joint dimensions and quantity unit so dissimilar systems are not combined under one area allowance.
Structural fireproofing
Requested output: Areas and specified thicknesses by member or assembly, with the agreed volume conversion stated.
Confirm in your quote: Issued protection schedule, member dimensions, exposed surfaces and allowance basis.
Penetration firestopping
Requested output: Counts by supplied penetration or system type, with identified sleeves and accessories.
Confirm in your quote: Services crossing rated assemblies, responsible trades and incomplete penetration schedules.
Joint firestopping
Requested output: Lengths by joint width, depth and specified assembly or system reference.
Confirm in your quote: Head-of-wall, perimeter and movement joints; access and masking responsibilities.
Estimating follows the project-specified systems. It does not select or certify a tested assembly, approve a fire rating or replace design-team, manufacturer, authority or inspection responsibilities.
Request this estimating scopeUS project coverage for fireproofing
For US projects, include the ZIP code and the location-sensitive inputs below.
- Provide the specified tested assemblies, product requirements and project-area supplier quotations.
- Identify access equipment, substrate preparation and specified inspection responsibility separately from coating area or penetration counts.
The proposal records the pricing date, cost sources and unconfirmed allowances. Explore US service area information or send your project details for a scope quote.
Use the document checklist above to request quantities only, a priced estimate or a review of an existing bid.
Request a fireproofing scope quoteScope coverage for your bid package
CSI Division 07 81 - Spray-Applied Fireproofing (SFRM)
Standard, medium, and high-density cementitious fireproofing on structural beams, columns, and metal decking.
CSI Division 07 81 23 - Intumescent Fireproofing (Thin-Film)
Architectural thin-film intumescent coatings for exposed structural steel, atriums, and canopies.
CSI Division 07 84 13 - Penetration Firestopping
Intumescent sealants, firestop pillows, composite sheets, wrap strips, and cast-in devices for MEP trades.
CSI Division 07 84 43 - Joint Firestopping (Safing)
Top-of-wall deflection joints, perimeter fire containment (curtain wall to slab edge), and expansion joints.
Rigid Board Fire Protection
Calcium silicate and mineral wool rigid boards for structural columns, grease ducts, and electrical circuits.
Thermal Barrier & Ignition Barrier Spray
Spray polyurethane foam (SPF) ignition and thermal barriers for attics and crawl spaces.
Sample CSI Division 07 80 Quantification Schedule
SFRM board footages, intumescent coating areas, firestop collars, and head-of-wall joints:
Worked estimating example. Quantities show the stated scope and format; this is not a client project or a project-specific price quote.
| CSI Scope Description | Quantity | Unit | Waste Allowance | Estimator Code Note |
|---|---|---|---|---|
| Division 07 81 00 - Spray-Applied Fire Resistive Material (SFRM) - 2-Hr Restrained Beams | 42,000 | BF | 25% Overspray | Monokote MK-6 / Isolatek Type 300 applied to 1-1/16in thickness |
| Division 07 81 23 - Thin-Film Intumescent Coating (Exposed Architectural Columns) | 2,400 | SF | 15% | Applied to 120 mils DFT for 2-hour rating per UL design |
| Division 07 84 13 - Penetration Firestop Collars (2-Hr Rated Restroom Stacks) | 140 | EA | N/A | Hilti CP 643N intumescent firestop collars for PVC/ABS waste lines |
| Division 07 84 43 - Joint Firestopping (Top of Rated Wall to Fluted Metal Deck) | 3,600 | LF | 8% | Mineral wool safing + spray elastic firestop sealant per UL HW-D series |
How your estimate is prepared
Send the structural drawings, the UL design references and the bid date. We measure SFRM, intumescent and firestopping scope against the rated assemblies, check primer compatibility where the notes call for it, and record the assumptions behind each quantity. How fireproofing quantities are checked sets out the review steps and version control behind the takeoff.
Estimating fees and delivery
Fireproofing fees scale with the rated area and the assembly mix — a single-floor SFRM package takes less estimating time than a high-rise with intumescent steel, penetration firestopping and perimeter safing across many floors. Fee and delivery date for the agreed fireproofing scope are confirmed in the written proposal before work begins.
| Scope / project type | Typical delivery | Typical fee |
|---|---|---|
| Single-trade material takeoff | Typically 24–48 hours after approval | $150–$1,000 typical |
| Residential construction estimate | Typically 2–4 business days after approval | $400–$1,000 typical |
| Commercial preconstruction package | Typically 3–5 business days after approval | $150–$1,000 typical |
| Industrial & heavy civil takeoff | Typically 4–7 business days after approval | $1,000–$5,000+ typical |
| Ongoing estimating support | Priority queue agreed in writing | $1,800/mo typical |
Fireproofing fees cover the takeoff work above. Rated area, assembly mix and deadline drive the written proposal.
Frequently asked questions
Do you calculate intumescent coating Dry Film Thickness (DFT) by steel W/D ratios?
Yes. Our fireproofing estimators calculate measured DFT thickness requirements (mils) based on each structural steel member's W/D (weight-to-heated perimeter) or A/P ratio and the specified 1, 2, or 3-hour fire rating per UL Design directories (e.g., UL X600 series).
Can you estimate Spray-Applied Fire Resistive Materials (SFRM) bag counts and yield?
Absolutely. We quantify both standard-density and medium/high-density cementitious and mineral-fiber SFRM (Monokote, Isolatek). We calculate measured board footage (BF), standard yield per bag, overspray waste allowances (20-30% on metal deck), and pump/rig staging labor.
How do you handle firestopping (Division 07 84 00) for MEP through-penetrations?
We count and categorize every pipe, conduit, busway, and duct penetration through fire-rated gypsum partitions and concrete floor decks, pairing each with certified UL system details (Hilti, 3M, STI) for intumescent sealants, firestop collars, composite sheets, and pillows.
Do your fireproofing takeoffs include steel surface prep, masking, and primer compatibility?
Yes. We evaluate structural notes for primer compatibility (alkyd vs. epoxy vs. bare steel) and quantify poly sheeting masking, overspray containment, scaffolding access, and daily cleanup labor.
What is your typical turnaround for a commercial fireproofing takeoff?
Delivery depends on the drawing set, requested trade scope, pricing requirements and bid deadline. The delivery date, scope and revision coverage are confirmed in the written quote after document review.
Coordinate related trades
Fireproofing follows structural steel and MEP penetrations — use the bid room for large or confidential drawing sets.