Squares by system · Foam roofs · Reflectance when specified
Phoenix roof squares stay split by system, and reflectance is only the product the spec named
Phoenix roofs are reviewed with the 2024 building and energy books that have applied at Planning & Development since 1 August 2025. Reflectance and insulation R-values come from the roof specification and the energy form. Heat explains why those notes are common. It does not let the takeoff swap in a cool-roof cap sheet the spec never named. Attachment zones are measured only where the spec defines field, perimeter, and corner. Otherwise the missing zone map is a gap.
Single-ply, sprayed foam, concrete tile, and metal are different squares and different slope factors. Foam roofs, frequent on older Valley buildings, need a thickness and a coating from the spec. A note that says recoat, with no mils, is a gap. Tile roofs need underlayment and battens as the detail shows them, not a membrane square. Cover board and crickets are board feet when thicknesses exist. Edge metal and scuppers are lengths and counts. Tear-off is in only when removal is this contract.
Roofers, Phoenix-Mesa-Chandler, May 2025 file OEUM003806000000047218103, hourly mean $24.86. Foam coating crews and tile crews may not match that broad title. The mean is not a price per square.
Send the roof plan and the system specification. No core is cut.
Crickets need thicknesses before they become board feet. A taper note without numbers is a gap. Expansion joints are lengths. Coping joints and pitch pans are counts. Walk pads and lightning conductors are not squares. They are counts or lengths if this contractor holds them. Pavers on pedestals are an area separate from the membrane under them. Skylight curbs are counts. Gutter expansion joints are counts. Foam coating mils, when the spec gives them, define the recoating quantity. Without mils the recoat is a gap rather than a guessed build-up.
Pipe boots and equipment curbs that penetrate the membrane are counts. A curb detail that belongs to the mechanical contractor is flagged so the roofer does not also own the curb steel. Counterflashing into a parapet is a length. Termination bar is a length. Walk-pad layout is a count of pads from the roof plan, not a percent of square. Lightning air terminals are counts if that scope is assigned here. Coating of an existing foam roof is an area at the mil thickness given. A second coat is not invented. Night seal during a tear-off is a means line only if you ask for it.
Roof squares before Valley foam and tile systems
Phoenix roof systems that should not share a square
Is every Phoenix roof a cool roof?
Only the assemblies whose specification or energy form names the reflectance. Others are quantified as drawn.
How is a foam roof measured?
As its own system, with thickness and coating when the spec gives them. A recoat note without mils is a gap, not a guessed build-up.
Is $24.86 per square?
No. Roofers in this wage area are listed at $24.86 on file OEUM003806000000047218103. Squares still need your production.