2021 IPC · 2021 IMC · 2026 NEC
Fort Worth systems quantities sit on a 2021 plumbing book, a 2021 mechanical book, and a 2026 electrical book
A combined mechanical, electrical, and plumbing takeoff for Fort Worth has to keep three adoption years apart. Development Services lists the 2021 International Plumbing Code and the 2021 International Fuel Gas Code, the 2021 International Mechanical Code, and the 2026 National Electrical Code effective September 1, 2026. Energy compliance is not a 2021 energy book. The city page allows the 2015 energy code or ASHRAE 90.1-2013, used entirely once chosen. A mechanical compliance report is required when heating, ventilating, air conditioning, or water heating is installed or altered. That report is not a substitute for the equipment schedule.
Plumbing fixtures, water piping, waste, and vent are measured from the plumbing sheets. Fuel gas stays out of the domestic total unless this contract holds the gas. Mechanical equipment is a count from the schedule. Duct is area or weight as drawn. Electrical gear is a count from the one-line. Shared equipment, such as a rooftop unit that needs a curb, a condensate line, and a power connection, is assigned once and cross-referenced so three trades do not each buy it.
Three metro figures are not averaged into one crew rate. Electricians are at $28.83 on series OEUM001910000000047211103. Plumbers, Pipefitters, and Steamfitters are at $29.94 on series OEUM001910000000047215203. Heating, Air Conditioning, and Refrigeration Mechanics and Installers are at $29.69 on series OEUM001910000000049902103. All three series are Dallas-Fort Worth-Arlington. Duct fabrication is another occupation and is not blended in. None of the three is a bid.
Kitchen hoods are counted from the hood drawings and kept apart from comfort-cooling duct. Makeup air for that hood is its own equipment line when the schedule tags it. Medical gas is not domestic water. Fire protection is out of this set unless the invitation includes the sprinkler sheets. A rooftop unit’s curb is noted once so the roof package is not also buying it. Condensate piping is linear by size from the mechanical diagram. Vibration isolators are counts from the detail. A boiler flue is a separate piece from the boiler. Outside-air connections are counted where the plans show the openings, not from a rule of thumb for the climate.
A Dallas electrical date or a Dallas energy edition copied onto a Fort Worth cover is the error this split is meant to catch. The assumption log names Fort Worth’s three years and then measures the lines.
Forward the plumbing, mechanical, and electrical sheets and say which energy path the forms use. No system is started.
A makeup-air unit serving a kitchen is equipment on the mechanical schedule and a duct run of its own, not a branch of the comfort system. Grease duct is linear from the hood to the discharge and is not comfort duct. Water-heater flues are counts. A boiler and its pumps are equipment. Condensate from an air handler is linear piping and is not the storm drain in the garage.
Systems quantities before treating Fort Worth as one code year
Fort Worth systems questions the three years create
Did the 2026 electrical code pull plumbing and mechanical forward with it?
No. The city page still lists 2021 plumbing and 2021 mechanical codes. Electrical is the 2026 NEC effective September 1, 2026.
Which energy book applies?
The city allows the 2015 energy code or ASHRAE 90.1-2013, and the chosen path is used in full. The forms in the set are what the log records.
Can the three wages be averaged?
No. The electrician, plumber, and mechanic series are separate metro figures. They are not one blended rate.