Member marks · 2021 building book · Miscellaneous metals apart
Fort Worth steel weight comes from the member marks, and the 2026 electrical book does not change a beam
A Fort Worth frame is weighed off the member schedule Development Services will see under the 2021 building code and the city’s amendments. The 2026 electrical adoption and the 2015 energy path belong to other sheets. They do not resize a wide-flange. Each column, girder, and brace is a mark with a shape and a cut length. Bolt groups, bearing plates, and rods cast into concrete are piece counts from the details that exist. A callout with no detail stays blank.
Bar joists and the deck they carry are kept out of the wide-flange total. Exit stairs, handrails, and ladder runs are a metals list, not tons. Plates cast in the slab are piece counts and are noted so the concrete bidder does not purchase them too. A canopy the architect drew and the engineer never sized is called undesigned. It is not assigned a made-up weight.
Primer is recorded when the spec requires a shop coat. Touch-up in the field is not treated as a full repaint of every surface. Light-gauge studs are not wide-flange and remain with framing unless your bid form pulls them onto this list. A yard screen stays on the metals list until a structural note gives it shapes.
Series OEUM001910000000047222103 records Structural Iron and Steel Workers at $27.88. That series is the Dallas-Fort Worth-Arlington survey. It is not a price per ton and it is not limited to the Fort Worth city limit. A private frame is not given a public wage schedule.
A delegated stair design that has not been issued is named as missing. Bridge crane rails, when the structural set shows them, are their own members and are not buried in the building beams. Galvanizing is a note from the spec, not a default for every exterior piece.
Forward the structural plans and the member schedule. No piece is field-measured.
A joist girder is listed with the joists, not thrown into the wide-flange tonnage. Bridging is a count or a length from the joist plan. Deck fasteners are noted only when the spec quantifies them. A lintel angle at a masonry opening is a piece with a length, and it is flagged so the mason is not also buying the steel. Roof frames for a screen are separate marks. A mansard of light-gauge metal is not rolled tonnage. Edge angle at a deck opening is linear. Moment connections are counts from the details that show bolts and plates. A stair that is still marked delegated is named and left without a weight.
Steel quantities before letting Fort Worth’s electrical code touch the tonnage
Fort Worth steel questions the schedule has to settle
Does the 2026 electrical code change the steel takeoff?
No. It is the electrical adoption. Beam weight still comes from the member marks under the 2021 building code.
Are stairs in the tonnage?
Exit stairs and rails stay on the metals list unless your bid form pulls them into the frame weight.
Is $27.88 a price per ton?
No. Series OEUM001910000000047222103 is the metro figure for Structural Iron and Steel Workers.