Veneer bands · Screen walls · Tilt panels excluded
Dallas masonry is the veneer and the screen wall, not the tilt panel standing next to them
Many Dallas shells cast the walls in concrete and then add a short brick band, an entry pier, or a yard screen. Development Services reviews that building under the 2021 code that took effect 12 May 2023. The cast walls are a concrete trade. This page counts only the unit masonry the elevations hatch. Summer heat changes how long the mortar stays workable. That is production, not an extra unit. Impact ratings belong on the roof specification, not on the brick count.
Load-bearing block is a unit count plus the grout and reinforcing the notes schedule. An equipment-yard screen is often shorter and a different bond than the entry veneer, so it is taken from that elevation alone. Flashing lengths and weep holes use the spacing the detail actually prints. If the detail gives no spacing, the weeps stay unresolved. Lintels are pieces. Access scaffolding is outside the mason’s number unless the invitation puts access there.
Brickmasons and Blockmasons across Dallas-Fort Worth-Arlington are listed at $26.94 on 2025 file OEUM001910000000047202103. The occupation title lumps veneer with screen-wall laying. It is not a unit price and it is not limited to the Dallas city limit.
A mockup panel is a count when the spec demands one. Washing new brick is an area when a cleaning section is actually in the book.
Upload the elevations that hatch the unit masonry and the wall sections. Cast-wall sheets alone are not enough. A soldier course at a head is a separate course count, not part of the running-bond field below it.
Shelf flashing is measured once at every floor the section repeats, which is more than a single building length on a multi-story veneer. Caps on a screen wall are piece counts. Bolts for a gate are counts when the mason installs them. The gate panel stays with metals unless the bid form says the mason buys it. Horizontal joint reinforcement is extended per course only after the note prints the vertical spacing. Solid-pier grout can be a volume from that pier schedule if you want material listed beside the units.
A brick wainscot that stops at a sill line is only the area below that line, not the full panel height. Stone at an entry pier is pieces or an area as the elevation dimensions it, and it is not converted into brick. Control joints in a long screen wall are lengths from that elevation. Caps on the screen wall are pieces. Gate leaves stay with miscellaneous metals unless the mason’s bid form says the mason buys the gate. Embedded bolts for the gate are counts when the mason sets them.
Masonry units before tilt-wall accents
Dallas masonry versus the tilt panel
Do cast walls belong in this masonry count?
No. Cast-in-place or tilt shells are concrete. This count is the unit masonry the elevations hatch.
Do you add weep holes for the weather?
No. Weep holes are counted from the spacing the detail prints. No spacing means the item stays open.
Is $26.94 a Dallas block price?
No. File OEUM001910000000047202103 is the metro hourly mean for brickmasons and blockmasons.