Cellar walls · Areaways · Vaults
Philadelphia waterproofing quantities are the areaway, the vault, and the cellar wall the detail actually dimensions
Below-grade work in Philadelphia shows up as cellar walls, areaways, and sidewalk vaults more often than as a deep modern basement. Licenses and Inspections reviews the building under the city’s amended code. The area still comes from the detail, not from the code section. A vault that is in the structural plan and assigned to this contract is an area of membrane or dampproofing to the height shown. A vault that is excluded by the limit of work stays out.
Dampproofing versus a full membrane follows the foundation detail and any geotechnical note on water. The city’s age and its rivers do not pick the system. Planter or roof-deck membranes, when a small roof deck is in the set, are a separate horizontal area. Waterstops at underpinning or new foundation joints are lengths from the structural details. Negative-side coatings on an existing cellar are an area only when a repair drawing shows them.
No 2025 wage-file occupation isolates this applicator in the metro table used here, so no mason or roofer figure is borrowed. Use your crew rate if you need labor. The quantity remains the area and the length.
Joint sealants at sidewalk hatches are lengths and are easy to leave in both the site package and this package. The log assigns them once.
Send foundation and vault details and the specification. No flood test is witnessed. Coal-chute openings that are being filled are a count of openings plus the masonry infill only when the repair sheet shows the fill.
Areaway drains and their leaders are counts and lengths and may belong to plumbing. The log gives them to one trade. Underpinning joints that need a waterstop are lengths from the structural underpinning sheet. A bilco or similar hatch is a count, and the membrane turn-up around it is a length of perimeter if the detail shows the turn-up. Stone window wells are not membrane area unless the detail wraps them. Back-parging on an existing rubble wall is an area only when a repair section shows the parging limits. A note that says make watertight, with no limits, is a gap.
Leaders from an areaway drain are lengths and are assigned to one trade in the log so plumbing does not also carry them. Underpinning waterstops are lengths from the underpinning sheet. Hatch perimeters are lengths of turn-up when the detail shows the turn-up. Window wells are membrane only if the detail wraps the well. Parging limits on a rubble cellar wall come from the repair section. A sentence that says make the cellar dry, with no boundary, stays open. Sidewalk hatch sealant is a length assigned once.
Below-grade areas before city vault details
Philadelphia below-grade scope that stops at the detail
Is every old cellar fully waterproofed?
No. The system and the height are whatever the detail dimensions. An undrawn coating is an exclusion.
Are sidewalk vaults always in the building number?
Only when the structural plan shows them inside your limit of work.
Which wage covers applicators?
None is taken from the wage file for this trade. Use your own rate.