F&K Estimatings Construction Estimating & Takeoffs

2024 UMC · Schedule equipment · No invented tons

Austin mechanical quantities follow the uniform mechanical code, and the cooling season does not add a unit the schedule omitted

Austin Development Services lists the Uniform Mechanical Code, 2024 edition, in the amendment table effective 10 July 2025. The table does not list an international mechanical code. Duct construction, equipment listing, and exhaust rules are read in the uniform book the specification names. A specification written to the international mechanical code is a clash to list, not a book to silently swap.

Air handlers, condensing units, rooftop units, fans, and energy-recovery units are counts from the equipment schedule. A long cooling season explains why the designer sized the machine. It does not authorize an extra machine the schedule never tagged. Outside-air connections and exhaust connections are separate from the cooling capacity. They are counted where the plans show the openings.

Sheet-metal duct is area or weight from the duct drawings, sized as drawn. Flex duct is linear where the plan uses flex. Diffusers, grilles, and louvers are each. Condensate receivers and pumps are each when the detail shows them. Refrigerant piping is linear by size from the piping diagram. Controls points are counted only when a points list is in the set. A missing points list is a gap.

File OEUM001242000000049902103 lists Heating, Air Conditioning, and Refrigeration Mechanics and Installers at $30.74. The survey geography is Austin-Round Rock-San Marcos. The title is the mechanic, not a ton of cooling and not a pound of duct. Sheet metal workers are a different occupation and are not averaged into this figure.

Kitchen hoods are counted from the hood drawings, and the exhaust duct from those drawings is kept apart from comfort-cooling duct. Makeup air serving that hood is its own equipment line when the schedule tags it. A generator radiator or a flue is not comfort cooling. Test and balance is a line only if you ask for it. Crane time for a rooftop unit is a general requirement you describe, not a hidden adder on the equipment count.

Insulation on duct and on refrigerant pipe follows the mechanical spec. The 2024 energy code may set a building envelope, but duct wrap is still the thickness the mechanical spec prints. A silent spec leaves the wrap unresolved.

Forward the equipment schedule, the duct plans, and the specification section. No equipment is started to see how it runs.

A garage exhaust fan is not the same line as a toilet exhaust. Stair pressurization, when the life-safety sheets show a fan, is equipment plus the duct that fan serves. Vibration isolation and a roof curb under a unit are counted from the detail, and the curb is noted so the roof trade is not also charged for buying it. Condensate pipe is linear by size from the diagram. A missing diagram leaves the pipe open. Filters are schedule counts, not a year’s supply, unless you ask for a maintenance stock.

Mechanical quantities before Austin’s uniform mechanical code

Austin mechanical items the heat does not add

Will you increase tonnage because Austin summers are long?

No. Equipment counts and capacities come from the schedule. A unit the schedule omitted stays omitted.

Is the international mechanical code the Austin book?

The amendment table effective 10 July 2025 names the 2024 uniform mechanical code. A set written to a different book is flagged.

Is $30.74 a price per ton?

No. File OEUM001242000000049902103 is the metro hourly figure for heating, air conditioning, and refrigeration mechanics and installers.

Austin mechanical references

Forward the Austin equipment schedule and duct plans

Request a quote for paid estimating or quantity takeoff services. Share your trade scope, project location and bid deadline. We confirm the fee and deliverables before work starts. Fields marked * are required.

Contact and project details
Choose your phone country and enter your local number. Or enter a full number starting with + and its country code, regardless of the country selected.

Project Drawings (optional)

PDF, CAD/BIM, Office, ZIP or image documents. Up to 5 files, 25 MB each; account limits also apply.

No drawings attached. This field is optional.

    Already have a sharing link? Paste it here instead of uploading. Grant access to info@fandkestimatings.us; do not include passwords.

    Upload only documents you are authorized to share. Privacy policy. This request does not opt you into marketing messages.

    Prefer to discuss the scope first, or having trouble with the form? Email your project details or discuss your project on WhatsApp. Include your project location, trade scope and bid deadline.