Philadelphia multi-family estimates measure each distinct plan once, then add the shared stairs and the party walls

Stacked houses and small apartment buildings in Philadelphia repeat plans and then break the pattern at the end units and the corner. Measure each distinct plan once, multiply by the count on the unit schedule, and add stairs, corridors, and the walls that separate neighbors. Licenses and Inspections is the city reviewer for a project inside the city, on the amended code tied to the 2021 models since the start of 2026. End units are not copies of the middle unit if the wall thickness or the window count changes.

Existing rowhouse conversions need a demolition limit and a new-work limit. Kitchens that remain are not in the new fixture count. Fire separations between units are the rated assemblies on the wall schedule, not a guess from the fact that people live next door. Roof bulkheads and stair penthouses are their own small volumes.

Cost Estimators in the Philadelphia-Camden-Wilmington wage area are published at $41.97 hourly mean, file OEUM003798000000013105103, 2025 release. That line does not price a unit. Public housing work uses the wage decision in the solicitation when the work is covered. A private rental rehab does not. The fee for the estimate is quoted from the set.

Amenity roofs and their membranes are not inside the unit area. They are measured from the roof plan if that scope is yours.

Send the unit matrix and the plans. No building is walked.

Light wells and rear ells change the window count on the plans that have them. Those plans are not multiplied as if they were the flat front unit. Cellar units, where the drawings include them, are a distinct plan with their own waterproofing and egress. Bulkheads over the stair are framed area plus roofing, not inside the top-floor unit. Meter banks and the electrical room are common area. They are measured once. Trash rooms and bike rooms are the same. A rear yard fence is sitework and stays out of the building number unless the invitation includes the site.

Fire escapes, where the elevation draws them, are a count of balconies and a length of stair, not a percent of units. Water heaters in a common closet are equipment counts, not one per dwelling, unless the plan shows one per dwelling. Electric meter stacks are a count from the electrical room. Rear-yard paving is left with sitework. A roof bulkhead is framed area plus a small roof, kept out of the top-floor unit. Window guards, if the schedule lists them, are counts of guards rather than of windows.

Multi-family estimates before rowhouse party walls

Philadelphia housing counts that should not be copied across units

Is every rowhouse in a row the same quantity?

Only when the plans say so. End units and corners are checked separately before the multiplier is applied.

Are party walls counted once or twice?

Once, on the side your contract owns, unless the drawings put work on both faces.

Does the estimator wage price a unit?

No. File OEUM003798000000013105103 is an hourly mean for cost estimators, not a cost per dwelling.

Philadelphia housing-estimate references

Send the Philadelphia unit plans and matrix

Share your project details. Fields marked * are required.

Contact and project details
Include + and your international calling code.

Project Drawings (optional)

PDF, CAD/BIM, Office, ZIP or image documents. Up to 5 files, 25 MB each; account limits also apply.

No drawings attached. This field is optional.

    Upload only documents you are authorized to share. Privacy policy. This request does not opt you into marketing messages.

    Prefer to discuss the scope first, or having trouble with the form? Email your project details or discuss your project on WhatsApp. Include your project location, trade scope and bid deadline.