Equipment schedule · 2021 commercial minimum · 2018 house minimum
Nashville mechanical quantities follow the equipment schedule, and a house is not on the same state minimum as a warehouse
Mechanical quantities for a Nashville building come from the equipment schedule and the duct plans. Since 17 April 2025 the State Fire Marshal’s minimum codes put commercial construction on the 2021 IBC with Tennessee amendments, and one- and two-family work on the 2018 IRC and the 2018 IECC. A city can adopt a different edition. This page does not claim Nashville’s ordinance matches the minimum, and it does not invent a department title. The workbook uses the edition the drawings name and says when that edition is silent.
Air handlers, rooftop units, and fans are counts from the tags. A humid summer and a tornado-season note do not add a unit. Outside air and exhaust are separate from cooling capacity. Duct is area or weight as drawn. Flex is linear where the plan uses it. Refrigerant piping is linear by size. Controls wait for a points list.
File OEUM003498000000049902103 lists Heating, Air Conditioning, and Refrigeration Mechanics and Installers at $29.39 for Nashville-Davidson-Murfreesboro-Franklin. Murfreesboro and Franklin are in the statistic and are other cities. The title is the mechanic, not a ton. The January 2023 chart limits Tennessee prevailing wage to highway construction over $50,000 and says non-highway construction has no state prevailing wage. A private mechanical package is non-highway. Davis-Bacon is a federal funding question.
Kitchen hoods stay with the hood drawings. Makeup air is its own tag. A flue is not comfort cooling. Condensate is linear. A curb is noted so the roof trade does not also buy it. Karst voids are a Middle Tennessee soils issue when the geotech says so. They do not change a fan count.
Test and balance is included only if you ask for it. A house mechanical plan and a warehouse mechanical plan in one PDF are logged as different code volumes until the drawings say otherwise. Frost is shallow here. Heat trace on an exterior pipe is linear only where the spec shows it.
Sheet-metal workers are a different occupation and are not folded into the mechanic figure. Duct insulation follows the mechanical spec. A clash with an energy form is reported.
Upload the schedule and the duct plans, and name the edition on the cover. No unit is started.
A rooftop unit screened by a masonry wall still counts as equipment. The screen is not sheet metal unless the mechanical details draw a metal screen. Split systems serving a historic house are one system per the cottage plan, not per the main hall.
A Nashville split system serving one house is the indoor unit, the outdoor unit, and the line set the plan dimensions, kept apart from a commercial rooftop unit on a warehouse in the same PDF. The warehouse unit is one each from its own schedule. Toilet exhaust in the house is not the warehouse makeup-air fan. Duct in the house is taken from the house layout. Duct in the warehouse is taken from the warehouse layout. A missing layout leaves that duct unresolved. Gas piping to a furnace is included only when the mechanical contract holds gas. A Franklin mechanical sheet is excluded. Test and balance is included only when you ask for it. The file lists equipment counts, duct measures, the house-versus-commercial code note, and the gaps.
Mechanical quantities before treating a Nashville house and warehouse as one code
Nashville mechanical questions the two minimums create
Is a Nashville house on the 2021 commercial minimum?
The fire marshal minimums keep one- and two-family work on the 2018 IRC. Commercial work is on the 2021 IBC minimum. A local adoption can differ. Use the edition the drawings name.
Does state prevailing wage apply to this mechanical package?
The January 2023 chart limits the state law to highway work over $50,000 and says non-highway construction has none. A building package is read that way unless the solicitation says it is highway work or federal.
Is $29.39 a price per ton?
No. Series OEUM003498000000049902103 is the survey hourly statistic for Heating, Air Conditioning, and Refrigeration Mechanics and Installers.