Furred masonry · Roof insulation · City energy path
Philadelphia insulation areas are often a furred face on an existing masonry wall, not a new cavity wall
Insulating a Philadelphia rowhouse or a small apartment block is often furring and batt or board on the inside of existing masonry, plus whatever the roof assembly shows. The energy path is the one in the filing under the city’s amendments to the statewide code that adopted the 2021 models at the start of 2026. A wall section from a new suburban cavity wall will not match. Measure the furred area to the height the section shows. A missing height is a gap, not a full-party-wall assumption that ignores floors.
Roof insulation, including any tapered crickets with printed thicknesses, is board feet and usually belongs with the roof contract. Leave it there unless this invitation holds it. Air sealing at window perimeters is a length if this trade owns the seal. Fire-safing at floors in a rated stair is a linear foot and often a different installer. Spray foam at a roof-wall joint is a small volume from the detail, not a coating on the whole facade.
Insulation Workers, Floor, Ceiling, and Wall in this wage area are at $27.02 hourly mean, 2025 file OEUM003798000000047213103. Pipe insulation is a different occupation and is not blended in. The figure is not a square-foot price. Covered public work uses the project determination.
Party-wall furring on one side is not automatically both sides. The plans show which face is in the contract.
Send the wall and roof sections and the energy forms. No one opens a party wall to see what is inside.
Kneewall insulation in a top-floor ell is an area of that kneewall, not of the whole roof. Floor insulation over an unconditioned cellar is an area of the first floor only where the section shows it. Rim joists at the front and rear are lengths. A party wall that is already furred on the neighbor’s side is still only your face if that is what the plan shows. Window returns on a deep masonry opening are lengths around the opening when this trade owns the return. Vapor retarder on the warm side is an area only when the section draws it. A silent section does not get a polyethylene sheet by habit.
Kneewalls in a top-floor ell are that ell’s area, not the whole roof. Insulation under the first floor, over a cold cellar, is only the area the section shows. Rim boards at the front and rear facades are lengths. Window returns in a thick masonry opening are perimeter lengths when this contract owns the return. A warm-side retarder is an area only if the section draws it. Closed-cell foam at the roof-to-wall joint is the small volume on that detail, not a facade coating. Your face of a party wall is the only face counted.
Insulation areas before furred masonry walls
Philadelphia insulation that is not a new cavity wall
Do you insulate both faces of a party wall?
Only the face the drawings put in your contract. The neighbor’s side is excluded unless it is drawn.
Is roof board inside the wall total?
Not when the roofing contract owns it. The invitation should say which contractor holds the roof insulation.
Does $27.02 buy the installed insulation?
No. It is the 2025 hourly mean for building insulation workers in the wage area.