F&K Estimatings Construction Estimating & Takeoffs
Source evidence & estimating method

Estimating Case Studies
& Scope Walkthroughs.

Start with case studies of the published source quantities and drawing references. Then explore separate representative scenarios explaining trade scope and bid-review questions.

Source-based case studies retain the approved sample data. The separate scenario walkthroughs use illustrative buildings, locations and figures. Neither collection claims a client bid result or verified savings.

Case studies from the published samples

Trace the drawing reference to the quantity and handoff

These published takeoff excerpts show quantities and drawing references. They are sample walkthroughs, not verified client outcomes. Priced examples use separate illustrative inputs.

Concrete footing: reconcile volume, reinforcement and formwork

Follow the recorded S1 / S4 references and check the footing volume against the dimensions in the source description.

See quantities and calculation notes

MEP handoff: distinguish pipe, duct and equipment power

Read three recorded items across plumbing, mechanical and electrical scope without combining their units or assigning the same responsibility twice.

See quantities and calculation notes

Commercial finishes: keep finish code and allowance together

Trace FT-03, FT-07 and WT-03 back to A2.03 and keep each product description with its saved quantity and allowance.

See quantities and calculation notes

Representative scope walkthroughs

The scenarios below explain typical estimating questions. Their project types, locations and figures are examples rather than records of client engagements.

Division 26 High-Rise Commercial
Focus
Feeders, risers, temp power

Electrical Estimate — 42-Story Office Tower

How we check a feeder schedule against NEC ampacity rules, price busway versus conduit-and-wire risers, coordinate cable tray, and carry temporary power as real scope.

Example: Chicago, IL
Read
Division 23 Healthcare
Focus
Seismic, ASHRAE 170, med gas

HVAC Estimate — 280-Bed California Hospital

Seismic restraint of MEP systems, a room-by-room ASHRAE 170 ventilation matrix, ICRA measures, and NFPA 99 medical gas with third-party verification.

Example: Los Angeles, CA
Read
Division 22 K-12 Education
Focus
Fixture counts, interceptor sizing

Plumbing Takeoff — 1,200-Student K-12 Campus

IPC minimum fixture counts worked out for a Group E occupancy, accessibility items that change rough-in, a PDI G101 interceptor sizing example, and Texas prevailing wage.

Example: Dallas-Fort Worth, TX
Read
Division 40 Industrial / Refinery
Focus
Weld counts, RT, shift factors

Process Piping Estimate — Refinery Turnaround

Quantities from P&IDs and isometrics, weld classification under ASME B31.3, radiographic testing priced from weld counts, and compounding productivity factors.

Example: Gulf Coast, TX
Read
Division 03 Parking / Mixed-Use
Focus
PT, lap splices, formwork

Concrete Estimate — Post-Tension Parking Garage

PT tendon quantities and local pricing, shoring versus flying tables, an ACI 318-19 Class B lap splice calculation, and coastal corrosion and connection details.

Example: Miami, FL
Read
MEP Coordination K-12 Education
Focus
Div 23 / Div 26 interface

The VFD Disconnect: Div 23 vs. Div 26 Scope Gap

How conflicting HVAC and electrical specifications leave VFD mounting, disconnects and control wiring unclaimed, and how a bid-leveling plug exposes it.

Example: Texas
Read
Division 03 Industrial
Focus
Cold-weather concreting

Cold-Weather Concrete: Pricing Heat, Protection and Yield

Pricing cold-weather protection under ACI 306, under-slab insulation that changes concrete yield, and documenting costs that were assumed to be incidental.

Example: Upstate New York
Read
Bid-Risk Management

Want This Method Applied to Your Project?

Send your drawings and specifications. We reply with a written quote, fee and delivery date, after document review.

Send drawings for a written quote

Include trades, location and bid deadline. We confirm fee and delivery before work starts.

Request a quote for paid estimating or quantity takeoff services. Share your trade scope, project location and bid deadline. We confirm the fee and deliverables before work starts. Fields marked * are required.

Contact and project details
Choose your phone country and enter your local number. Or enter a full number starting with + and its country code, regardless of the country selected.

Project Drawings (optional)

PDF, CAD/BIM, Office, ZIP or image documents. Up to 5 files, 25 MB each; account limits also apply.

No drawings attached. This field is optional.

    Already have a sharing link? Paste it here instead of uploading. Grant access to info@fandkestimatings.us; do not include passwords.

    Upload only documents you are authorized to share. Privacy policy. This request does not opt you into marketing messages.

    Prefer to discuss the scope first, or having trouble with the form? Email your project details or discuss your project on WhatsApp. Include your project location, trade scope and bid deadline.