HVAC tenders in Qatar span new distribution on building projects and chiller or AHU replacement in live facilities. F&K measures remote HVAC estimating packages that keep equipment, ductwork, piping, controls and temporary cooling separable for Qatari riyal pricing.
Remote estimating for Qatar projects. This page does not represent a local office.
Updated · F&K estimating methodology
Equipment schedules and layouts must agree before pricing fans
Plant schedules may show capacities while layouts show terminal counts that imply different airflow paths. A takeoff that trusts only one sheet will misstate duct surface area and diffuser counts. F&K reconciles both and raises conflicts as clarifications instead of averaging them into a quiet number.
Insulation, vibration isolation and condensate drainage are frequent Qatar HVAC bill items that vanish inside equipment rates. In coastal and high-load conditions, those accessories matter. They stay on their own lines when specified, and stay out when the tender places them elsewhere. The written quote remains the scope authority, so undocumented extras are never implied by market custom alone.
What the takeoff can include
Primary plant
Count chillers, AHUs, FAHUs, pumps and fans from schedules with installation-only tags identified.
Ductwork and fittings
Measure duct by size or surface area per the bill rules, with fittings and dampers listed as required.
Hydronic piping
Separate chilled-water and condenser-water pipe by diameter, including valves and specialties.
Controls and balancing
Carry control points, sensors and testing/balancing allowances only where assigned to the HVAC package.
Measurement and scope checks
HVAC measurement uses a system tree: plant, distribution, terminals, controls. Renewal jobs add a strip-out branch. Bill item codes remain the primary keys for public tenders. QAR rates attach after quantities and temporary provisions are agreed in the quote. The workbook also records open clarifications so a missing detail does not silently become a firm quantity. Where freight, customs or mobilisation affect industrial cash flow more than measured units, those cost inputs stay outside the quantity columns until you provide a quotation basis.
Illustrative AHU replacement quantity map
One air-handling unit is replaced while duct mains remain.
| Component | Document basis | Workbook line |
|---|---|---|
| AHU-3 replacement | Schedule shows new unit | 1 supply and install; old unit strip-out separate. |
| Main duct reuse | Layout marks existing | No new duct area; transition pieces only. |
| VAV terminals | 14 new on branch ducts | 14 terminals plus associated controls points. |
Illustrative only. Fire dampers, smoke control and TAB responsibilities follow the issued specification.
Deliverable, pricing basis and quote
HVAC workbooks can be quantities-only or priced in QAR. The quote defines whether insulation, controls and temporary cooling are included. Typical turnaround is 24–48 hours from a complete mechanical package. Revision rounds after addenda reprice only the affected lines, and the fee for those rounds is confirmed before remeasurement starts. Send addenda as they arrive if you need mid-tender updates.
Explore our full hvac estimating services scopeQuestions about this scope
Can you exclude controls from an HVAC takeoff?
Yes. Controls can be interface notes only when another specialist carries the BMS package.
Do you size ductwork?
No. We measure what the drawings show. Duct design remains with the mechanical engineer.
How are spare parts handled?
Commissioning spares appear only when the tender lists them or you request a stated allowance.
Can the workbook stay quantities-only through tender?
Yes. Many bid teams apply their own rates locally. Quantities-only delivery still includes assumptions, drawing references and an addenda log.
Official project references
- Ashghal e-Tenders
HVAC public packages inherit the tender's measurement and submission rules.