F&K Estimatings Construction Estimating & Takeoffs

Finish legend · Separate materials · No invented wage

Columbus floor areas follow the finish legend, and humidity is not a moisture product the spec never named

Columbus, Georgia floor quantities come from the finish legend, not from the 1 January 2026 code change. Inspections & Code reviews the building. The legend picks the product. A flame-spread limit in the spec is an occupancy rule, not permission to substitute a cheaper good.

Sheet goods, carpet, wood, and tile each keep a column even in a single room. Transition strips and base are lengths by material. Removal of an old finish is its own area. A slab moisture treatment appears only when the spec requires the test or the product. Humidity is not that spec.

The wage extract used here has no Columbus, Georgia row for floor layers or for tile setters. Both are omitted rather than borrowed from a larger Georgia metro. The January 2023 chart shows no Georgia prevailing-wage statute. Private tenant floors do not pick up a public scale.

Stair treads are a count or an area as the finish plan dimensions them. Landings are not folded into the stair. Wall tile is not floor tile. A raised access floor, panels and pedestals, is its own system and is not the carpet that may sit on it. Epoxy in a kitchen or a lab is only the rooms the spec names.

A gym floor with a pad and a wood surface is two layers. Thresholds at sliders are linear. Balcony coatings that belong to the deck trade stay out unless the finish spec assigns them here. An Alabama parcel stapled into the set is flagged.

Colors and products change when the legend changes product, not every time a room number changes. Attic stock is a count only when the spec states a percentage or a quantity. Otherwise it stays off the list.

Upload the finish plan and the flooring specification. No slab is tested from here.

Dance-floor sprung systems are a separate assembly from the concrete below them. Athletic line paint on wood is not resilient flooring. A terrazzo divider strip is linear. Mat recesses at entries are counts. A raised dais in a sanctuary is its own area.

Floor areas before inventing a Columbus moisture system

Columbus floor questions the legend has to answer

Do you add a slab-moisture system because the city is humid?

No. Testing and mitigation are quantified when the specification requires them. Climate is not a substitute for that section.

Which wage covers Columbus floor layers?

None is printed here. The May 2025 extract has no Columbus, Georgia row for that work.

Is wall tile part of the floor area?

No. Wall tile stays with the wall finish unless this invitation gives the floor trade the wainscot.

Columbus flooring references

Upload the Columbus finish plan

Share your project details. Fields marked * are required.

Contact and project details
Include + and your international calling code.

Project Drawings (optional)

PDF, CAD/BIM, Office, ZIP or image documents. Up to 5 files, 25 MB each; account limits also apply.

No drawings attached. This field is optional.

    Upload only documents you are authorized to share. Privacy policy. This request does not opt you into marketing messages.

    Prefer to discuss the scope first, or having trouble with the form? Email your project details or discuss your project on WhatsApp. Include your project location, trade scope and bid deadline.